Cylinder Less Tube Based Fire Suppression System
Cylinder Less Tube Based Fire Suppression System
Cylinder Less Tube Based Fire Suppression System
Cylinder Less Tube Based Fire Suppression System
Cylinder Less Tube Based Fire Suppression System
Cylinder Less Tube Based Fire Suppression System

Cylinder Less Tube Based Fire Suppression System

Price 15000 INR/ Piece

MOQ : 1 Piece

Cylinder Less Tube Based Fire Suppression System Specification

  • Fire Class
  • A, B, C, E
  • Connectivity Type
  • Standalone, Optional Electrical Alarm Contacts
  • Working Temperature
  • -10C to +60C
  • Energy Efficiency Rating
  • Passive Standalone (No Power Required Operationally)
  • Voltage
  • Not required for basic operation (alarm: 12V/24V DC when integrated)
  • Installation Type
  • Wall Mount, Integrated within Equipment Cabinets
  • Fire Extinguisher Type
  • Clean Agent (e.g., Novec 1230, FM200, HFC-227ea)
  • Technology
  • Polymer Detection Tube-Based, Cylinderless System
  • Control Type
  • Automatic, Mechanical Activation
  • Shape
  • Flexible Tube with Rectangular/Box Control Unit
  • Mounting Type
  • Surface Mount
  • Features
  • Direct Release, Early Automatic Detection, No High-Pressure Cylinder Required, Compact Design
  • Coating Type
  • UV Resistant Polymer Tube
  • Coverage Area
  • Up to 2 cubic meters per tube loop (expandable)
  • Operating Pressure
  • 8-18 bar
  • Application
  • Localized Fire Suppression, Electrical Panels, Server Racks, Small Enclosures
  • Max Flow Rate
  • Depends on agent and system design (typical: 10-25 L/min)
  • Diameter
  • 8 mm to 18 mm (tube) / 50 mm control unit approx.
  • Capacity
  • 1 kg to 5 kg agent, based on enclosure size
  • Pressure
  • 8-18 bar (tube working pressure)
  • Compliance Standards
  • UL Listed Components, CE Marked, RoHS Compliant
  • Life Span of Tube
  • 5-7 years under normal conditions
  • Noise Level
  • Silent in Standby, Moderate discharge noise
  • Activation Time
  • Immediate upon tube exposure to flame or 100C-120C
  • Detection Method
  • Thermo-sensitive Polymer Tube Rupture
  • Agent Discharge Method
  • Direct at Flame Source via Burst Point
  • Agent Compatibility
  • Novec 1230, FM200, HFC-227ea, ABC Dry Powder
  • Weight (System)
  • 3 kg to 9 kg depending on configuration
  • Color
  • Red Tube, Grey/Black Control Unit
  • Maintenance
  • Minimal, Monthly Visual Inspection Recommended
 

Cylinder Less Tube Based Fire Suppression System Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

Cylinder Less Tube Based Fire Suppression System About



Redeem advanced fire safety with this premier Cylinder Less Tube Based Fire Suppression System, offering superior protection for electrical panels, server racks, and compact enclosures. Top-rated for its immediate response, the system utilizes a breathtaking thermo-sensitive polymer tube that ruptures at direct flame exposure or 100C-120C, releasing agent directly at the source-no high-pressure cylinders required. Enjoy minimal maintenance and a life span of 5-7 years. Find confidence with UL listed components, CE marking, and RoHS compliance. Compatible with premier agents like Novec 1230 and FM200, installation is effortless, energy-efficient, and highly reliable for Indian industrial and commercial environments.

Strategic Application Sites & User Guidance

This Cylinder Less Tube Based Fire Suppression System is perfect for use in electrical panels, server racks, and small enclosures. Preferred by manufacturers, data centers, and electrical maintenance professionals across India, it's designed for straightforward surface or cabinet-mounting. Simply position the flexible, UV-resistant polymer tube near potential ignition points and secure the control unit for automatic, immediate fire detection and suppression. Enjoy peace of mind with minimal interference in your daily operations.


Packaging, Market Reach & Sample Policy

Each unit is delivered in robust packaging for secure shipping and minimal risk during transportation. We ensure prompt delivery throughout the main domestic market, especially across key industrial zones in India. Sample policies allow interested customers to evaluate a product upon request, ensuring confidence before bulk purchase. The compact design makes transportation manageable, while each package includes clear instructions for effortless integration at your site.


FAQ's of Cylinder Less Tube Based Fire Suppression System:


Q: How does the Cylinder Less Tube Based Fire Suppression System activate in case of a fire?

A: The system automatically activates when the thermo-sensitive polymer tube is exposed to a flame or reaches 100C-120C. Upon rupture, it immediately discharges the selected fire suppression agent directly at the flame source.

Q: What types of fire classes can this system effectively suppress?

A: It is designed to handle Class A, B, C, and E fires (solids, flammable liquids, gases, and electrical types) with suitable agents like Novec 1230, FM200, HFC-227ea, or ABC Dry Powder.

Q: When should the system be inspected and maintained?

A: A visual inspection is recommended monthly, but the system requires minimal maintenance overall. The polymer detection tube has a superior lifespan of 5-7 years under normal conditions.

Q: Where can this suppression system be installed for optimal effectiveness?

A: It is ideal for localized fire suppression within electrical panels, server racks, and small enclosed equipment cabinets-anywhere that demands compact, direct, and automatic fire protection.

Q: What are the benefits of choosing a cylinderless, polymer tube technology system?

A: This system offers direct release to the flame source, early automatic detection, a compact design, no high-pressure cylinders, and operates passively without continuous power-making installation and maintenance simple and cost-effective.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Suppression Systems Category

Bus Engine Fire Suppression System

Bus Engine Fire Suppression System

Price 75000 INR / Set

Minimum Order Quantity : 1 Set

Application : Bus Engine Compartments

Control Type : Automatic & Manual Control

Technology : Automatic Detection and Suppression (Tubebased/Linear Heat Detection)

Fire Extinguisher Type : Clean Agent or Dry Chemical (ABC, FK5112, FM 200, Dry Powder)

Co2 Flooding System Fire Suppression System

Co2 Flooding System Fire Suppression System

Price 110000 INR / Set

Minimum Order Quantity : 1 Set

Application : Industrial fire protection, power plants, generator rooms, data centers

Control Type : Automatic and manual

Technology : Total flooding with automatic or manual discharge

Fire Extinguisher Type : CO2 Total Flooding System

Co2 Flooding System

Co2 Flooding System

Price 45000 INR / Set

Minimum Order Quantity : 1 Set

Application : Industrial Fire Protection, Power Plants, Data Centers, Warehouses, Electrical Panels, Marine & Shipping Areas

Control Type : Automatic and Manual Control (Electrically or Mechanically actuated)

Technology : Total Flooding, Automated or Manual Release System

Fire Extinguisher Type : CO2 Flooding System (High Pressure Carbon Dioxide)

Gas Suppression System

Gas Suppression System

Price 250000 INR / Set

Minimum Order Quantity : 1 Set

Application : Server Rooms, Data Centers, Control Rooms, Industrial Facilities

Control Type : Automatic with Manual Override

Technology : Clean Agent Gas Suppression (FM200, Novec 1230, Inert Gas)

Fire Extinguisher Type : Automatic Modular Gas Based



arrow